Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Diagn+Interv+Radiol 2017 ; 23 (5): 333-8 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Lesion characteristics, histopathologic results, and follow-up of breast lesions after MRI-guided biopsy #MMPMID28830847
Ta?k?n F; Soyder A; Tanyeri A; Öztürk VS; Ünsal A
Diagn Interv Radiol 2017[Sep]; 23 (5): 333-8 PMID28830847show ga
PURPOSE: We aimed to assess the effectiveness of magnetic resonance imaging (MRI)-guided vacuum-assisted breast biopsy (VABB), evaluate and compare the characteristics and histopathologic findings of lesions, and overview the follow-up results of benign lesions. METHODS: MRI findings and histopathologic results of breast lesions biopsied by MRI-guided VABB between 2013 and 2016 were retrospectively analyzed. MRI findings closely related with malignancy were investigated in particular. Follow-up results of benign lesions were evaluated. RESULTS: MRI-guided VABB was applied to 116 lesions of 112 women. Of the lesions, 75 (65%) were benign, while 41 (35%) were malignant. Segmental (94%), clustered (89%), and clustered ring (67%) non-mass- like enhancement patterns were found to be more related with malignancy. False-negative rate of MRI-guided VABB was 12%, underestimation rate was 21%. One of the 54 followed-up benign lesions had a malignant result. CONCLUSION: MRI-guided VABB is a reliable method for the diagnosis of breast lesions that are positive only on MRI. Follow-up results show that cancer detection rate is low for radio-pathologically concordant lesions. Further multicenter studies with larger patient population are needed to elucidate these results.