Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Warning: imagejpeg(C:\Inetpub\vhosts\kidney.de\httpdocs\phplern\28469932.jpg): Failed to open stream: No such file or directory in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 117 J+Pharm+Health+Care+Sci 2017 ; 3 (ä): ä Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Evaluation of the permeation of antineoplastic agents through medical gloves of varying materials and thickness and with varying surface treatments #MMPMID28469932
J Pharm Health Care Sci 2017[]; 3 (ä): ä PMID28469932show ga
Background: Medical gloves are an important piece of personal protective equipment that prevents exposure to antineoplastic agents. The permeability of medical gloves to antineoplastic agents is a crucial factor in the appropriate selection of gloves. However, the relationship between glove permeability and material type, thickness, and surface treatment is poorly understood. Methods: A continuous flow in-line cell device was used for the evaluation of the permeation of five antineoplastic agents (etoposide, cyclophosphamide, doxorubicin hydrochloride, paclitaxel, and fluorouracil) through medical gloves. Medical gloves made of three types of materials (chlorinated latex, non-chlorinated latex, and nitrile) were subjected to a permeability test. The antineoplastic agents in test solutions were tested at the highest concentrations employed in general clinical practice. Then, the relationship between glove thickness and permeability was assessed using chlorinated latex gloves with thicknesses of 0.1, 0.15, 0.2, and 0.1 mm?×?2 (to represent the practice of ?double gloving?). Results: Only cyclophosphamide and fluorouracil showed detectable permeation through the tested latex gloves. The permeability of chlorinated latex was lower than that of non-chlorinated latex. Nitrile gloves showed no detectable permeability to any of the five antineoplastic agents tested. The permeability of chlorinated latex gloves depended on the thickness of the gloves; 0.1 mm?×?2 (double gloving) exhibited the highest resistance to permeation by antineoplastic agents. Conclusions: The permeability of medical gloves was dependent on the type of material and the surface treatment and decreased as the thickness of the glove increased. The double glove was shown to prevent antineoplastic agent permeation more efficiently than did a single glove of the same total thickness. These results provided important information that will guide the appropriate selection of medical gloves.