Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Clin+Mol+Hepatol 2017 ; 23 (1): 34-41 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Transient elastography versus hepatic venous pressure gradient for diagnosing portal hypertension: a systematic review and meta-analysis #MMPMID28263953
Kim G; Kim MY; Baik SK
Clin Mol Hepatol 2017[Mar]; 23 (1): 34-41 PMID28263953show ga
Background/Aims: Transient elastography (TE) has been proposed as a promising noninvasive alternative to hepatic venous pressure gradient (HVPG) for detecting portal hypertension (PH). However, previous studies have yielded conflicting results. We gathered evidence from literature on the clinical usefulness of TE versus HVPG for assessing PH. Methods: We conducted a systematic review by searching databases for relevant literature evaluating the clinical usefulness of non-invasive TE for assessing PH in patients with cirrhosis. A literature search in Ovid Medline, EMBASE and the Cochrane Library was performed for all studies published prior to December 30, 2015. Results: Eight studies (1,356 patients) met our inclusion criteria. For the detection of PH (HVPG ?6 mmHg), the summary sensitivity and specificity were 0.88 (95% confidence interval [CI] 0.86-0.90) and 0.74 (95% CI 0.67-0.81), respectively. Regarding clinically significant PH (HVPG ?10 mmHg), the summary sensitivity and specificity were 0.85 (95% CI 0.63-0.97) and 0.71 (95% CI 0.50-0.93), respectively. The overall correlation estimate of TE and HVPG was large (0.75, 95% CI: 0.65; 0.82, P<0.0001). Conclusions: TE showed high accuracy and correlation for detecting the severity of PH. Therefore, TE shows promise as a reliable and non-invasive procedure for the evaluation of PH that should be integrated into clinical practice.