Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Ophthalmic+Vis+Res 2016 ; 11 (3): 287-95 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Role of Fine Needle Aspiration Cytology as a Diagnostic Tool in Orbital and Adnexal Lesions #MMPMID27621787
J Ophthalmic Vis Res 2016[Jul]; 11 (3): 287-95 PMID27621787show ga
Purpose:: To evaluate the role of fine needle aspiration (FNAC) as a diagnostic tool in cases of orbital and ocular adnexal masses. Cytological findings were correlated with histopathological diagnosis wherever possible. Methods:: FNAC was performed in 29 patients of different age groups presenting with orbital and ocular adnexal masses. Patients were evaluated clinically and investigated by non-invasive techniques before fine needle aspiration of the masses. Smears were analyzed by a cytologist in all cases. Further, results of cytology were compared with the histopathological diagnosis. Results:: The age of patients ranged from 1 to 68 years (mean: 29.79±19.29). There were 14 males and 15 females with a male to female ratio of 0.93:1. Out of 29 cases, 26 aspirates were cellular. Cellularity was insufficient in three (10.34%) aspirates. Out of 26 cellular aspirates, 11 were non-neoplastic while 15 were neoplastic on cytology. Subsequent histopathologic examination was done in 21/26 cases. Concordance rate of FNAC in orbital and ocular adnexal mass lesions with respect to the precise histologic diagnosis was 90%. Conclusion:: When properly used in well-indicated patients (in cases where a diagnosis cannot be made by clinical and imaging findings alone), FNAC of orbital and periorbital lesions is an invaluable and suitable adjunct diagnostic technique that necessitates close cooperation between the ophthalmologist and cytologist. However, nondiagnostic aspirates may sometimes be obtained, and an inconclusive FNAC should not always be ignored.