Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1007/s10195-016-0394-y

http://scihub22266oqcxt.onion/10.1007/s10195-016-0394-y
suck pdf from google scholar
C4999372!4999372!26883439
unlimited free pdf from europmc26883439    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 229.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid26883439      J+Orthop+Traumatol 2016 ; 17 (3): 249-54
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Steinmann pin augmentation versus locking plate constructs #MMPMID26883439
  • Ruskin J; Caravaggi P; Beebe KS; Corgan S; Chen L; Yoon RS; Patterson FR; Hwang JS
  • J Orthop Traumatol 2016[Sep]; 17 (3): 249-54 PMID26883439show ga
  • Background: Aggressive bone neoplasms, such as giant cell tumors, often affect the proximal tibia warranting bony resection via curettage leaving behind massive defects that require extensive reconstruction. Reconstruction is usually accomplished with poly(methyl methacrylate) (PMMA) packing supplemented with an internal fixation construct. The purpose of this study is to compare Steinmann pin augmentation to locking plate constructs to determine which offers the stiffer reconstruction option. Materials and methods: Large defects were created below the lateral condyle of fresh frozen tibias. The defects extended for an average of 35 mm beneath the lateral plateau in the frontal plane, and from the anterior to posterior cortex in the sagittal plane. Distally the defect extended for an average of 35 mm to the metadiaphyseal junction. In the Pin group, the tibias were reconstructed with three 4-mm diameter Steinmann pins placed in the medullary canal and PMMA packing. In the Plate group, the tibias were reconstructed with a 6-hole 3.5-mm LCP Proximal locking plate fixed to the proximal?lateral tibia utilizing seven 3.5-mm screws and PMMA packing. The tibias were tested for stiffness on a MTS machine by applying up to 400 N to the tibial plateau in force control at 5 N/s. Fatigue properties were tested by applying a haversine loading waveform between 200 N and 1,200 N at 3 Hz simulating walking upstairs/downstairs. Results: Locking plate constructs (801.8 ± 78 N/mm) had greater (p = 0.041) stiffness than tibial constructs fixed with Steinmann pins (646.5 ± 206.3 N/mm). Conclusions: Permanent deformation was similar between the Pin and Plate group; however, two tibia from the Pin group exhibited displacements >5 mm which we considered failure. Level of evidence: n/a.
  • ä


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box