Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1055/s-0035-1565926

http://scihub22266oqcxt.onion/10.1055/s-0035-1565926
suck pdf from google scholar
C4626231!4626231!26649262
unlimited free pdf from europmc26649262    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid26649262      J+Wrist+Surg 2015 ; 4 (4): 292-300
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Volar, Intramedullary, and Percutaneous Fixation of Distal Radius Fractures #MMPMID26649262
  • Alluri R; Longacre M; Pannell W; Stevanovic M; Ghiassi A
  • J Wrist Surg 2015[Nov]; 4 (4): 292-300 PMID26649262show ga
  • Background?The management of extra-articular distal radius fractures is highly variable, with no clear consensus regarding their optimal management.Purpose?To assess comparatively the biomechanical stability of Kirschner wire (K-wire) fixation, volar plating, and intramedullary nailing for unstable, extra-articular distal radius fractures with both (1) constant and (2) cyclical axial compression, simulating forces experienced during early postoperative rehabilitation.Methods?Twenty-six volar locking plate, intramedullary nail, and K-wire bone-implant constructs were biomechanically assessed using an unstable extra-articular distal radius bone model. Bone implant models were created for each type of construct. Three samples from each construct underwent compressive axial loading until fixation failure. The remaining samples from each construct underwent fatigue testing with a 50-N force for 2,000 cycles followed by repeat compressive axial loading until fixation failure.Results?Axial loading revealed the volar plate was significantly stiffer than the intramedullary nail and K-wire constructs. Both the volar plate and intramedullary nail required greater than 300?N of force for fixation failure, while the K-wire construct failed at less than 150 N. Both the volar plate and intramedullary nail demonstrated less than 1?mm of displacement during cyclic loading, while the K-wire construct displaced greater than 3 mm. Postfatigue testing demonstrated the volar plate was stiffer than the intramedullary nail and K-wire constructs, and both the volar plate and intramedullary nail required greater than 300?N of force for fixation failure while the K-wire construct failed at less than 150 N.Conclusions?Volar plating of unstable extra-articular distal radius fractures is biomechanically stiffer than K-wire and intramedullary fixation. Both the volar plate and intramedullary nail demonstrated the necessary stability and stiffness to maintain anatomic reduction during the postoperative rehabilitation period.Clinical Relevance?Both the volar plate and intramedullary nail demonstrated the necessary biomechanical stability to maintain postoperative reduction in extra-articular distal radius fractures, warranting further clinical comparison.
  • ä


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box