Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.5812/ircmj.15603

http://scihub22266oqcxt.onion/10.5812/ircmj.15603
suck pdf from google scholar
C4028777!4028777!24910804
unlimited free pdf from europmc24910804    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid24910804      Iran+Red+Crescent+Med+J 2014 ; 16 (4): ä
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Design and Construct an Optical Device to Determine Relative Blood Volume in Patients Undergoing Hemodialysis #MMPMID24910804
  • Dormanesh B; Tofangchiha S; Abouei V; Sharifian H
  • Iran Red Crescent Med J 2014[Apr]; 16 (4): ä PMID24910804show ga
  • Background:: Occurrence of hypotension during hemodialysis in nearly 20-30% of patients, shows is the necessity of continuous monitoring the patients' blood pressure during hemodialysis. Since directly and non-invasively continuous blood pressure monitoring, is not easy, finding a parameter related to blood pressure, for indirect monitoring is of great value. Related blood volume (RBV) is one of the parameters, related to blood pressure and have a good potential to reflect the patient?s hemodynamic condition. Objectives:: The main objective of this study was to design and construct an optical device to determine the RBV in patients undergoing hemodialysis, during the process. Materials and Methods:: After initial studies in order to select a proper sensor, using the ORCAD software, an analog circuit was designed. The implementation and modification of the circuit was done by the clinical tests, using expired blood. Afterwards, for calculation the RBV, controlling the display, data storage and sending it to the computer, an ATmega16 microcontroller was used. For programing the microcontroller, CodeVision software and then Altium Designer software were used for the circuit compression, in order to design the printed circuit board. Finally, all parts of the analog and digital circuit, AC to DC converter and the LCD were embedded in a box. Results:: After finalization of the device and before testing it in a real situation, expired blood was used for final evaluation. The evaluation was done by changing the blood concentration, at the start point by adding water to it. In fact, the device can track the changes in blood concentration and display the RBV. After this evaluation, the device was tested in a clinical situation. The results showed there are no interactions between this device and the other devices used in the dialysis section and it can work properly in order to measure the RBV. Conclusions:: Considering the hypotension and its consequences in a patient on hemodialysis, solving this problem seems necessary. One method for preventing this, is to use the blood pressure related parameters and one of these parameters is the RBV. In this study, in order to measure the RBV, a device was designed and evaluated by expired blood and also tested in a clinical situation. Results showed that the device could work properly in order to measure the RBV.
  • ä


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box