Warning: file_get_contents(https://eutils.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&id=40784197&cmd=llinks): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 215
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Warning: imagejpeg(C:\Inetpub\vhosts\kidney.de\httpdocs\phplern\40784197.jpg): Failed to open stream: No such file or directory in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 117 J+Clin+Virol 2025 ; 180 (ä): 105850 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Comparison of diagnostic performances of HDV-RNA quantification assays used in clinical practice: Results from a national quality control multicenter study #MMPMID40784197
J Clin Virol 2025[Aug]; 180 (ä): 105850 PMID40784197show ga
INTRODUCTION: A reliable quantification of hepatitis D virus (HDV) RNA is of paramount importance for monitoring patients under antiviral therapy. This quality control study compares the diagnostic performances of quantitative HDV-RNA assays used in clinical practice. METHODS: Two HDV-RNA sample panels were quantified in 30 centers by RoboGene (N = 9 laboratories), EurobioPlex (N = 7), RealStar (N = 4), AltoStar (N = 1), Bosphore (N = 3), Bosphore-on-InGenius (N = 1), Dia.Pro (N = 2), Nuclear-Laser-Medicine (N = 1) and 3 in-house assays. Panel A and B comprised 8 serial dilutions of WHO/HDV standard (range: 0.5-5.0 log10 IU/ml) and 20 clinical samples (range: 0.5-6.0 log10 IU/ml), respectively. The following parameters were determined: sensitivity by 95 % LOD (limit of detection), precision by intra- and inter-run CV (coefficient of variation), accuracy by the differences between expected-observed HDV-RNA, linearity by linear regression analysis. RESULTS: 95 % LOD varied across assays and centers underlining heterogeneous sensitivities: AltoStar had the lowest 95 % LOD (3 IU/ml) followed by RealStar (10 [min-max: 3-316] IU/ml), Bosphore-on-InGenius (10 IU/ml), RoboGene (31 [3-316] IU/ml), Nuclear-Laser-Medicine (31 IU/ml) and EuroBioplex (100 [100-316] IU/ml). Moreover, 6 assays (RoboGene, EurobioPlex, RealStar, AltoStar, Nuclear-Laser-Medicine and In-house) showed <0.5 log10 IU/ml differences between expected and observed HDV-RNA for all dilutions while other assays had >1 log10 IU/ml underestimations. RealStar, Bosphore-on-InGenius and EurobioPlex had the highest precision (mean intra-run CV < 20 %). Inter-run CV was higher for all assays, with CVs < 25 % for RealStar, AltoStar, Nuclear-Laser-Medicine and EurobioPlex. Seven assays (RoboGene/AltoStar/RealStar/EurobioPlex/Nuclear-Laser-Medicine/In-house) showed a good linearity (R(2) > 0.90), but for HDV-RNA < 1000 IU/ml only Bosphore-on-InGenius, AltoStar, RealStar and Robogene showed a R(2) > 0.85. CONCLUSIONS: This study underlines heterogeneous sensitivities (inter- and intraassays), that could hamper proper HDV-RNA quantification, particularly at low viral loads. This raises the need to improve the diagnostic performance of most assays for properly identifying virological response to anti-HDV drugs.