Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1016/j.ajic.2021.08.003

http://scihub22266oqcxt.onion/10.1016/j.ajic.2021.08.003
suck pdf from google scholar
34390799!8408652!34390799
unlimited free pdf from europmc34390799    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid34390799      Am+J+Infect+Control 2021 ; 49 (12): 1506-1510
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Evaluating and contextualizing the efficacy of portable HEPA filtration units in small exam rooms #MMPMID34390799
  • Pirkle S; Bozarth S; Robinson N; Hester W; Wagner L; Broome S; Allen K; Mannepalli S
  • Am J Infect Control 2021[Dec]; 49 (12): 1506-1510 PMID34390799show ga
  • BACKGROUND: Ambulatory clinics attend to COVID-19 patients, often in spaces with less than ideal ventilation. Testing and treatments can often include aerosol-generating procedures. Portable high efficiency particulate air (HEPA) filtration units have been used to remove airborne contaminants in these areas. METHODS: A particle counter was used to evaluate the effectiveness of portable HEPA filtration units when a proxy airborne contaminant (powder) was actuated into the air. The Center for Disease Control and Prevention's (CDC) Airborne Contaminant Removal table served as a basis for initial particle readings at 6 minutes. RESULTS: Percent decrease was calculated post powder actuation at the 6-minute and 12-minute mark. There was a statistically significant decrease in smaller particles at the 6-minute and 12-minute mark when the HEPA filtration units were used. CONCLUSION: As an adjunct infection control intervention, portable HEPA filtration units can make outpatient exam rooms safer for patients and staff by decreasing cumulative airborne particles.
  • |*Air Pollution, Indoor[MESH]
  • |*COVID-19[MESH]
  • |Aerosols[MESH]
  • |Filtration[MESH]
  • |Humans[MESH]
  • |Infection Control[MESH]
  • |SARS-CoV-2[MESH]