Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Clin+Chem+Lab+Med 2021 ; 59 (12): 2003-2009 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Performance evaluation of an automated SARS-CoV-2 Ag test for the diagnosis of COVID-19 infection on nasopharyngeal swabs #MMPMID34331847
Hartard C; Berger S; Josse T; Schvoerer E; Jeulin H
Clin Chem Lab Med 2021[Nov]; 59 (12): 2003-2009 PMID34331847show ga
OBJECTIVES: The detection of SARS-CoV-2 in infected people is a key tool to help in controlling COVID-19 pandemic. Like rapid antigenic tests, automated antigen tests, that present the advantage of a higher throughput flow, may be of interest. The LIAISON((R)) SARS-CoV-2 Ag test was evaluated for the quantification of SARS-CoV-2 nucleocapsid antigen in nasopharyngeal swabs by comparison to RT-PCR. METHODS: The study involved 378 nasopharyngeal samples (UTM((R)) and FLOQSwab, Copan Diagnostics), including 46 swabs positive for SARS-CoV-2 by RT-PCR. These samples came from asymptomatic (n=99, 26.2%) or symptomatic people (n=279, 73.8%), at different times from symptom onset. The samples were analyzed on LIAISON((R)) XL. RESULTS: The overall specificity was 99.4% (CI95% [98.6-100]). The negative predictive value reached 100% in asymptomatic people. Among the 46 positive samples, the overall sensitivity was 84.8% (CI95% [74.4-95.2]), reached 91.9% (CI95% [83.1-100]) in the first fourth days after symptoms onset and was 100% for Cq values =25. Antigen was not detected in samples with Cq values >25. Similar results were observed on nasopharyngeal swabs coming from patients infected with the 20I/501Y.V1 variant or the 20H/501Y.V2 variant. CONCLUSIONS: According to technical performances, the LIAISON((R)) SARS-CoV-2 Ag test may be a useful tool for COVID-19 diagnosis, especially during the first four days of symptoms.