Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 300.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 300.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Med+Virol 2021 ; 93 (12): 6837-6840 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Comparison of SARS-CoV-2 detection with the Cobas(R) 6800/8800 system on gargle samples using two sample processing methods with combined oropharyngeal/nasopharyngeal swab #MMPMID34324212
Benoit P; Labbe AC; Lalancette L; Gagnon S; Bonneau E; Lavallee C; Roger M; Fafard J; Dumaresq J; Beauchemin S; Coutlee F
J Med Virol 2021[Dec]; 93 (12): 6837-6840 PMID34324212show ga
BACKGROUND: Gargle samples have been proposed as a noninvasive method for detection of SARS-CoV-2 RNA. The clinical performance of gargle specimens diluted in Cobas(R) PCR Media and in Cobas(R) Omni Lysis Reagent was compared to oropharyngeal/nasopharyngeal swab (ONPS) for the detection of SARS-CoV-2 RNA. STUDY DESIGN: Participants were recruited prospectively in two COVID-19 screening clinics. In addition to the ONPS, participants gargled with 5 ml of natural spring water split in the laboratory as follows: 1 ml was added to 4.3 ml of polymerase chain reaction (PCR) media and 400 mul was added to 200 mul of lysis buffer. Testing was performed with the Cobas(R) SARS-CoV-2 test on the Cobas(R) 6800 or 8800 platforms. RESULTS: Overall, 134/647 (20.7%) participants were considered infected because the ONPS or at least one gargle test was positive. ONPS had, respectively, a sensitivity of 96.3% (95% confidence interval [CI]: 91.3-98.5); both gargle processing methods were slightly less but equally sensitive (90.3% [95% CI: 83.9-94.3]). When ONPS and gargle specimens were both positive, the mean cycle threshold (C(t) ) was significantly higher for gargles, suggesting lower viral loads. CONCLUSION: Gargle specimens directly added in PCR Media provide a similar clinical sensitivity to chemical lysis, both having a slightly, not significantly, lower sensitivity to ONPS.