Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1007/s00540-021-02965-1

http://scihub22266oqcxt.onion/10.1007/s00540-021-02965-1
suck pdf from google scholar
34169361!8224990!34169361
unlimited free pdf from europmc34169361    free
PDF from PMC    free
html from PMC    free

Warning: file_get_contents(https://eutils.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&id=34169361&cmd=llinks): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 215

suck abstract from ncbi

pmid34169361      J+Anesth 2021 ; 35 (4): 586-590
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Glucose control using an artificial pancreas in a severe COVID-19 patient on extracorporeal membrane oxygenation: a case report #MMPMID34169361
  • Hinoue T; Yatabe T; Fujiwara H; Nishida O
  • J Anesth 2021[Aug]; 35 (4): 586-590 PMID34169361show ga
  • The usefulness and safety of continuous glucose monitoring (CGM) systems in adult patients with severe coronavirus disease (COVID-19) have been reported. Using CGM might reduce the exposure patients and healthcare workers to COVID-19 and limit the use of personal protective equipment during the pandemic. CGM devices measure glucose in the subcutaneous interstitial fluid, but the accuracy of this technique has not been established in critically ill patients. The artificial pancreas, STG-55 (Nikkiso, Tokyo), is a closed-loop device that conducts continuous blood glucose monitoring using a peripheral vein. We used the STG-55 for glucose control in a 60-year-old woman with severe COVID-19 admitted to the intensive care unit. Due to severe respiratory failure, the patient was intubated, and extracorporeal membrane oxygenation was introduced. Because she had hyperglycemia despite high-dose intravenous insulin therapy, we decided to use STG-55 for glucose control. The STG-55 safely titrated the insulin infusion and monitored glucose levels. Fifty-six hours after adopting the STG-55, it was removed because the blood sampling failed. No episodes of hypoglycemia were observed despite deep sedation during this period. In conclusion, this case demonstrates the potential utility of an artificial pancreas in patients with severe COVID-19.
  • |*COVID-19[MESH]
  • |*Extracorporeal Membrane Oxygenation[MESH]
  • |*Pancreas, Artificial[MESH]
  • |Adult[MESH]
  • |Blood Glucose[MESH]
  • |Blood Glucose Self-Monitoring[MESH]
  • |Female[MESH]
  • |Humans[MESH]
  • |Insulin[MESH]
  • |Middle Aged[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box