Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1111/ijcp.14524

http://scihub22266oqcxt.onion/10.1111/ijcp.14524
suck pdf from google scholar
34120388!8420246!34120388
unlimited free pdf from europmc34120388    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid34120388      Int+J+Clin+Pract 2021 ; 75 (10): e14524
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Comparison of rapid antibody test and thorax computed tomography results in patients who underwent RT-PCR with the pre-diagnosis of COVID-19 #MMPMID34120388
  • Kiziloglu I; Sener A; Siliv N
  • Int J Clin Pract 2021[Oct]; 75 (10): e14524 PMID34120388show ga
  • INTRODUCTION: In this study, it is planned to compare the real-time reverse transcription-polymerase chain reaction (RT-PCR) test, which is the gold standard in the diagnosis of COVID-19, with thorax computed tomography (CT) and rapid antibody test results. METHODS: Patients who were admitted to the emergency service of Izmir Cigli Training and Research Hospital between 01.04.2020 and 31.05.2020 and who were suspected of having COVID-19 infection were included in the study. The medical records of the patients were retrospectively analysed through the hospital data processing database. Age, gender, hospitalisation, status of home quarantine, real-time RT-PCR, thorax CT and rapid antibody test results of the patients were examined. The relationship between RT-PCR, thorax CT and rapid antibody test results was compared statistically. RESULTS: A total of 181 patients, 115 (63.5%) male and 66 (36.5%) female, with an average age of 56.4 +/- 18.06 years were included in the study. The nasopharyngeal swab PCR result obtained at the first admission of the patients to the emergency department was positive in 71 (39.2%) patients. Rapid antibody tests performed at hospital admission were positive in 57 (31.5%) patients. Thorax CT was performed in 173 (95.6%) patients who applied to the emergency department, and 112 (64.7%) of them had findings that could be compatible with COVID-19. According to the thorax CT findings in patients, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting COVID-19 infection were, respectively, 76.1%, 43.1%, 48.2% and 72.1% (k: 0.176, P < .001). According to the rapid antibody test results, sensitivity, specificity, PPV and NPV for detecting COVID-19 infection were 57.5%, 85.5%, 71.9% and 75.8%, respectively (k: 0.448, P < .001). In our study, the mortality rate for COVID-19 was found to be 2.8%. CONCLUSION: Rapid antibody test and thorax CT examinations were found to have low diagnostic value in patients who admitted to the emergency department of our hospital and whose first RT-PCR SARS-CoV-2 test was positive. Studies involving larger patient groups are needed for their use alone in diagnosis and screening.
  • |*COVID-19[MESH]
  • |Adult[MESH]
  • |Aged[MESH]
  • |Female[MESH]
  • |Humans[MESH]
  • |Male[MESH]
  • |Middle Aged[MESH]
  • |Retrospective Studies[MESH]
  • |Reverse Transcriptase Polymerase Chain Reaction[MESH]
  • |SARS-CoV-2[MESH]
  • |Sensitivity and Specificity[MESH]
  • |Thorax/diagnostic imaging[MESH]