Detection of SARS-CoV-2 IgG antibodies in dried blood spots #MMPMID34116343
Diagn Microbiol Infect Dis 2021[Sep]; 101 (1): 115425 PMID34116343show ga
The COVID-19 pandemic led to development of numerous serologic tests. To obviate the need for phlebotomy services, we validated dried blood spots (DBS) for anti-SARS-CoV-2 serologic testing. Immunoglobulins were extracted from 3 mm DBS punches and the extracts were analyzed using the Euroimmun anti-SARS-CoV-2 IgG ELISA. Various pre-analytical factors were studied. Results were favorable for DBS stored for at least 67 days at or below 37 degrees C. Comparison between paired serum and DBS specimens tested by the Euroimmun ELISA showed 96.8% and 81.3% positive and negative agreement, respectively, indicating that confirmatory testing of positive Euroimmun results on DBS extracts is necessary to achieve clinical accuracy. Our findings suggest that any SARS-CoV-2 antibody assay that requires pre-dilution of serum is amenable to DBS as an alternate specimen type that is relatively low cost, self-collectable, stable, can be shipped by standard mail and could be used to establish the seroprevalence of large populations.