Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 251.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Biosens+Bioelectron 2021 ; 187 (ä): 113330 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Rapid and highly sensitive one-tube colorimetric RT-LAMP assay for visual detection of SARS-CoV-2 RNA #MMPMID34022500
He Y; Xie T; Tong Y
Biosens Bioelectron 2021[Sep]; 187 (ä): 113330 PMID34022500show ga
Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) is a highly contagious disease. To tame the continuously raging outbreak of COVID-19, developing a cheap, rapid and sensitive testing assay is absolutely imperative. Herein, we developed a one-tube colorimetric RT-LAMP assay for the visual detection of SARS-CoV-2 RNA. The assay integrates Si-OH magnetic beads (MBs)-based fast RNA extraction and rapid isothermal amplification in a single tube, thus bypassing the RNA elution step and directly amplifying on-beads RNA molecules with the visualized results. This one-tube assay has a limit of detection (LOD) as low as 200 copies/mL for sample input volumes of up to 600 muL, and can be performed in less than 1 h from sample collection to result readout. This assay demonstrated a 100% concordance with the gold standard test RT-qPCR test by using 29 clinical specimens and showed high specificity. This one-tube colorimetric RT-LAMP assay can serve as an alternative platform for a rapid and sensitive diagnostic test for COVID-19 and is particularly suitable for use at community clinics or township hospitals.