Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Pract+Lab+Med 2021 ; 25 (ä): e00234 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Analysis of SARS-CoV-2 antibodies from dried blood spot samples with the Roche Elecsys Immunochemistry method #MMPMID33942023
Fontaine E; Saez C
Pract Lab Med 2021[May]; 25 (ä): e00234 PMID33942023show ga
OBJECTIVES: The aim of this study was to evaluate the application of the Roche Elecsys anti-SARS-CoV-2 assay to capillary dried blood samples for high throughput analyses on Roche COBAS 6000 systems. DESIGN AND METHODS: The performance of the of the Elecsys anti-SARS-CoV-2 assay was assessed using three sets of dried blood spot samples. Method correlation was performed using spiked blood samples. Sensitivity and specificity were calculated using paired donor samples. An additional cohort of 50 individuals, including COVID-19 convalescent cases, was used for the evaluation of at-home collection for mail transport, and stability studies. RESULTS: The Elecsys anti-SARS-CoV-2 assay using dried blood spot samples showed an excellent agreement of 98.9% with results obtained using their paired serum samples, and 86.7% accuracy with dried blood spots collected after 9 days from diagnostic (PCR) tests. CONCLUSIONS: Capillary dried blood spot samples can be confidently used on Roche COBAS automated analyzers to monitor the epidemiology of COVID-19, and are suitable for use in large-scale screening programs.