Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1016/j.cca.2021.04.016

http://scihub22266oqcxt.onion/10.1016/j.cca.2021.04.016
suck pdf from google scholar
33930425!8078036!33930425
unlimited free pdf from europmc33930425    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33930425      Clin+Chim+Acta 2021 ; 519 (ä): 133-139
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Evaluation of 32 rapid tests for detection of antibodies against SARS-CoV-2 #MMPMID33930425
  • Tollanes MC; Jenum PA; Kierkegaard H; Abildsnes E; Baevre-Jensen RM; Breivik AC; Sandberg S
  • Clin Chim Acta 2021[Aug]; 519 (ä): 133-139 PMID33930425show ga
  • AIMS: To evaluate the analytical performance of 32 rapid tests for detection of antibodies against coronavirus SARS-CoV-2. MATERIALS AND METHODS: We used at total of 262 serum samples (197 pre-pandemic and 65 convalescent COVID-19), and three criteria to evaluate the rapid tests under standardized and optimal conditions: (i) Immunoglobulin G (IgG) specificity "good" if lower limit of the 95% confidence interval was >/= 97.0%, "acceptable" if point estimate was >/= 97.0%, otherwise "not acceptable". (ii) IgG sensitivity "good" if point estimate was >/= 90.0%, "acceptable" if >/= 85.0%, otherwise "not acceptable". (iii) User-friendliness "not acceptable" if complicated to perform or difficult to read result, otherwise "good". We also included partial evaluations of three automated immunoassay systems. RESULTS: Sensitivity and specificity varied considerably; IgG specificity between 90.9% (85.9-94.2) and 100% (97.7-100.0), and IgG sensitivity between 53.8% (41.9-65.4) and 98.5% (91.0-100.0). Combining our evaluation criteria, none of the 28 rapid tests that detected IgG had an overall performance considered "good", seven tests were considered "acceptable", while 21 tests were considered "not acceptable". Four tests detected only total antibodies and were not given an overall evaluation. IgG sensitivity and/or specificity of the automated immunoassays did not exceed that of many rapid tests. CONCLUSION: When prevalence is low, the most important analytical property is a test's IgG specificity, which must be high to minimize false positive results. Out of 32 rapid tests, none had a performance classified as "good", but seven were classified as "acceptable".
  • |*COVID-19[MESH]
  • |*SARS-CoV-2[MESH]
  • |Antibodies, Viral[MESH]
  • |Humans[MESH]
  • |Immunoassay[MESH]
  • |Immunoglobulin M[MESH]
  • |Pandemics[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box