Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1016/j.chest.2021.04.023

http://scihub22266oqcxt.onion/10.1016/j.chest.2021.04.023
suck pdf from google scholar
33895130!8463654!33895130
unlimited free pdf from europmc33895130    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33895130      Chest 2021 ; 160 (4): 1388-1396
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Mitigation of Aerosols Generated During Exercise Testing With a Portable High-Efficiency Particulate Air Filter With Fume Hood #MMPMID33895130
  • Garzona-Navas A; Sajgalik P; Csecs I; Askew JW; Lopez-Jimenez F; Niven AS; Johnson BD; Allison TG
  • Chest 2021[Oct]; 160 (4): 1388-1396 PMID33895130show ga
  • BACKGROUND: The role of portable high-efficiency particulate air (HEPA) filters for supplemental aerosol mitigation during exercise testing is unknown and might be relevant during COVID-19 pandemic. RESEARCH QUESTION: What is the effect of portable HEPA filtering on aerosol concentration during exercise testing and its efficiency in reducing room clearance time in a clinical exercise testing laboratory? STUDY DESIGN AND METHODS: Subjects were six healthy volunteers aged 20 to 56 years. In the first experiment, exercise was performed in a small tent with controlled airflow with the use of a stationary cycle, portable HEPA filter with fume hood, and particle counter to document aerosol concentration. Subjects performed a four-stage maximal exercise test that lasted 12 min plus 5 min of pretest quiet breathing and 3 min of active recovery. First, they exercised without mitigation then with portable HEPA filter running. In a separate experiment, room aerosol clearance time was measured in a clinical exercise testing laboratory by filling it with artificially generated aerosols and measuring time to 99.9% aerosol clearance with heating, ventilation, and air conditioning (HVAC) only or HVAC plus portable HEPA filter running. RESULTS: In the exercise experiment, particle concentrations reached 1,722 +/- 1,484/L vs 96 +/- 124/L (P < .04) for all particles (>0.3 mum), 1,339 +/- 1,281/L vs 76 +/- 104/L (P < .05) for smaller particles (0.3 to 1.0 mum), and 333 +/- 209/L vs 17 +/- 19/L (P < .01) for larger particles (1.0 to 5.0 mum) at the end of the protocol in a comparison of mitigation vs portable HEPA filter. Use of a portable HEPA filter in a clinical exercise laboratory clearance experiment reduced aerosol clearance time 47% vs HVAC alone. INTERPRETATION: The portable HEPA filter reduced the concentration of aerosols generated during exercise testing by 96% +/- 2% for all particle sizes and reduced aerosol room clearance time in clinical exercise testing laboratories. Portable HEPA filters therefore might be useful in clinical exercise testing laboratories to reduce the risk of COVID-19 transmission.
  • |*Air Filters[MESH]
  • |*Pandemics[MESH]
  • |Adult[MESH]
  • |Aerosols/*analysis[MESH]
  • |Air Conditioning/*methods[MESH]
  • |COVID-19/*diagnosis/metabolism[MESH]
  • |Female[MESH]
  • |Healthy Volunteers[MESH]
  • |Humans[MESH]
  • |Male[MESH]
  • |Middle Aged[MESH]
  • |Particle Size[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box