Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1016/S1473-3099(21)00146-8

http://scihub22266oqcxt.onion/10.1016/S1473-3099(21)00146-8
suck pdf from google scholar
33857405!8041361!33857405
unlimited free pdf from europmc33857405    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 217.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 251.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 251.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 251.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 251.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33857405      Lancet+Infect+Dis 2021 ; 21 (9): 1233-1245
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Diagnostic performance of different sampling approaches for SARS-CoV-2 RT-PCR testing: a systematic review and meta-analysis #MMPMID33857405
  • Tsang NNY; So HC; Ng KY; Cowling BJ; Leung GM; Ip DKM
  • Lancet Infect Dis 2021[Sep]; 21 (9): 1233-1245 PMID33857405show ga
  • BACKGROUND: The comparative performance of different clinical sampling methods for diagnosis of SARS-CoV-2 infection by RT-PCR among populations with suspected infection remains unclear. This meta-analysis aims to systematically compare the diagnostic performance of different clinical specimen collection methods. METHODS: In this systematic review and meta-analysis, we systematically searched PubMed, Embase, MEDLINE, Web of Science, medRxiv, bioRxiv, SSRN, and Research Square from Jan 1, 2000, to Nov 16, 2020. We included original clinical studies that examined the performance of nasopharyngeal swabs and any additional respiratory specimens for the diagnosis of SARS-CoV-2 infection among individuals presenting in ambulatory care. Studies without data on paired samples, or those that only examined different samples from confirmed SARS-CoV-2 cases were not useful for examining diagnostic performance of a test and were excluded. Diagnostic performance, including sensitivity, specificity, positive predictive value, and negative predictive value, was examined using random effects models and double arcsine transformation. FINDINGS: Of the 5577 studies identified in our search, 23 studies including 7973 participants with 16 762 respiratory samples were included. Respiratory specimens examined in these studies included 7973 nasopharyngeal swabs, 1622 nasal swabs, 6110 saliva samples, 338 throat swabs, and 719 pooled nasal and throat swabs. Using nasopharyngeal swabs as the gold standard, pooled nasal and throat swabs gave the highest sensitivity of 97% (95% CI 93-100), whereas lower sensitivities were achieved by saliva (85%, 75-93) and nasal swabs (86%, 77-93) and a much lower sensitivity by throat swabs (68%, 35-94). A comparably high positive predictive value was obtained by pooled nasal and throat (97%, 90-100) and nasal swabs (96%, 87-100) and a slightly lower positive predictive value by saliva (93%, 88-97). Throat swabs have the lowest positive predictive value of 75% (95% CI 45-96). Comparably high specificities (range 97-99%) and negative predictive value (range 95-99%) were observed among different clinical specimens. Comparison between health-care-worker collection and self-collection for pooled nasal and throat swabs and nasal swabs showed comparable diagnostic performance. No significant heterogeneity was observed in the analysis of pooled nasal and throat swabs and throat swabs, whereas moderate to substantial heterogeneity (I(2) >/=30%) was observed in studies on saliva and nasal swabs. INTERPRETATION: Our review suggests that, compared with the gold standard of nasopharyngeal swabs, pooled nasal and throat swabs offered the best diagnostic performance of the alternative sampling approaches for diagnosis of SARS-CoV-2 infection in ambulatory care. Saliva and nasal swabs gave comparable and very good diagnostic performance and are clinically acceptable alternative specimen collection methods. Throat swabs gave a much lower sensitivity and positive predictive value and should not be recommended. Self-collection for pooled nasal and throat swabs and nasal swabs was not associated with any significant impairment of diagnostic accuracy. Our results also provide a useful reference framework for the proper interpretation of SARS-CoV-2 testing results using different clinical specimens. FUNDING: Hong Kong Research Grants Council.
  • |*SARS-CoV-2[MESH]
  • |COVID-19 Nucleic Acid Testing/*methods[MESH]
  • |COVID-19/*diagnosis[MESH]
  • |Humans[MESH]
  • |Nasopharynx/virology[MESH]
  • |Oropharynx/virology[MESH]
  • |Pharynx/virology[MESH]
  • |Predictive Value of Tests[MESH]
  • |Saliva/virology[MESH]
  • |Sensitivity and Specificity[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box