Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 332.4 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+AOAC+Int 2021 ; 104 (4): 935-947 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Validation of the Thermo Scientific SARS-CoV-2 RT-PCR Detection Workflow for the Detection of SARS-CoV-2 from Stainless-Steel Environmental Surface Swabs: AOAC Performance Tested MethodSM 012103 #MMPMID33822958
J AOAC Int 2021[Aug]; 104 (4): 935-947 PMID33822958show ga
BACKGROUND: The Thermo Scientific SARS-CoV-2 reverse transcription-polymerase chain reaction (RT-PCR) Detection Workflow, packaged with Applied Biosystems TaqMan 2019-nCoV Assay Kit v1 targets three different SARS-CoV-2 genomic regions in a single RT-PCR reaction. OBJECTIVE: To validate the Thermo Scientific SARS-CoV-2 RT-PCR Workflow, for the detection of SARS-CoV-2 virus on stainless-steel surfaces as part of the AOAC Performance Tested MethodSM Emergency Response Validation program. METHOD: The Applied Biosystems TaqMan 2019-nCoV Assay Kit v1, as part of the Thermo Scientific SARS-CoV-2 RT-PCR Workflow, was evaluated for specificity using in silico analysis of 15 764 SARS-CoV-2 sequences and 65 exclusivity organisms. The Thermo Scientific SARS-CoV-2 RT-PCR Workflow was evaluated in an unpaired study for one environmental surface (stainless steel) and compared to the U.S. Centers for Disease Control and Prevention 2019-Novel Coronavirus RT-PCR Diagnostic Panel, Instructions for Use (Revision 4, Effective 6/12/2020). RESULTS: In silico analysis showed that, of the 15 756 target SARS-CoV-2 genomes analyzed, 99% of the strains/isolates are perfectly matched to at least two of the three assays, and more than 90% have 100% homology to all three assays (ORF1ab, N-gene, S-gene) in the SARS-CoV-2 Kit. None of the 65 non-target strain genomes analyzed showed matching sequences. In the matrix study, the Thermo Scientific SARS-CoV-2 workflow showed comparable detection to the centers of disease control and prevention (CDC) method. CONCLUSIONS: The Thermo Scientific SARS-CoV-2 RT-PCR Workflow is an effective procedure for detection of RNA from SARS-CoV-2 virus from stainless steel. HIGHLIGHTS: The workflow provides equivalent performance results with the two tested RNA extraction platforms and the two tested RT-PCR instruments.