Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Waste+Dispos+Sustain+Energy 2021 ; 3 (2): 177-183 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Incineration experiment of medical waste of novel coronavirus pneumonia (COVID-19) in a mobile animal carcass incinerator #MMPMID33688621
Zhang S; Zhang Y; Wang F; Kang D; Wang J; Wang M; Zhang C; Wang Y; Liu H; Zhou B; Wu Y
Waste Dispos Sustain Energy 2021[]; 3 (2): 177-183 PMID33688621show ga
Incineration experiment of medical waste was carried out in a mobile animal carcass incinerator. Simulated medical waste (69% cotton, 1.5% wood product, 4.5% mask and 25% moisture) was used as raw material. The temperature trend of first and second combustion chamber, the operating conditions and the emission characteristics of gaseous pollutants were studied. The results indicated that the temperature of first combustion chamber can be maintained at 550-650 degrees C without external heating, while in the final stage a burner was used to realize the burnout of material. The temperature of the second combustion chamber was always lower than that of the first combustion after the burner stopped working. The concentration of CO emission in flue gas was high due to the low disposal efficiency of the mobile incinerator, while NO(X) and SO(2) emission concentrations were far below the standard limit value (GB 18484-2001).