Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 213.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 247.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 280.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 280.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 280.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 280.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Pharm+Biomed+Anal 2021 ; 196 (ä): 113924 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Combination of the NanoSuit method and gold/platinum particle-based lateral flow assay for quantitative and highly sensitive diagnosis using a desktop scanning electron microscope #MMPMID33581588
Kawasaki H; Suzuki H; Maekawa M; Hariyama T
J Pharm Biomed Anal 2021[Mar]; 196 (ä): 113924 PMID33581588show ga
Owing to its simplicity and low cost, the lateral flow assay (LFA) is one of the most commonly used point-of-care diagnostic techniques, despite its low sensitivity and poor quantification. Here, we report a newly developed LFA-NanoSuit method (LNSM) combined with a desktop scanning electron microscope (SEM) for the direct observation of immunocomplexes labeled with a colloidal metal instead of signal enhancement strategies, such as using color, electrochemical signals, silver enhancement, magnetic properties, luminescent, and surface-enhanced Raman spectroscopy (SERS). The proposed LNSM suppresses cellulose deformity, thereby allowing the acquisition of high-resolution images of gold/platinum-labeled immunocomplexed pathogens such as influenza A, without conductive treatment as in conventional SEM. Electron microscopy-based diagnosis of influenza A exhibited 94 % clinical sensitivity (29/31; 95 % confidence interval [CI]: 79.3-98.2 %) and 100 % clinical specificity (95 % CI: 98.1-100 %), which was more sensitive (71.4 %) than visual detection (14.3 %), especially in the lower influenza A-RNA copy number group. The detection ability of our method was nearly comparable to that of real-time reverse transcription-PCR. This is the first report on the diagnosis of clinical diseases using LFA equipped with a desktop SEM. This simple and highly sensitive quantitative analysis method involving LFA can be used to diagnose various diseases in humans and livestock, including highly infectious diseases such as COVID-19.