Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 227.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Med+Virol 2021 ; 93 (5): 3268-3272 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Self-collected saliva for SARS-CoV-2 detection: A prospective study in the emergency room #MMPMID33527375
Echavarria M; Reyes NS; Rodriguez PE; Ypas M; Ricarte C; Rodriguez MP; Perez MG; Seoane A; Martinez A; Videla C; Stryjewski ME; Carballal G
J Med Virol 2021[May]; 93 (5): 3268-3272 PMID33527375show ga
Current diagnostic standards involve severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection in nasopharyngeal swabs (NPS), but saliva is an attractive and noninvasive option for diagnosis. The objectives were to determine the performance of saliva in comparison with NPS for detecting SARS-CoV-2 and to compare the optimized home brew reverse-transcription polymerase chain reaction (RT-PCR) with a commercial RT-PCR. Paired NPS and saliva specimens were prospectively collected and tested by RT-PCR from patients presenting at an emergency room with signs and symptoms compatible with coronavirus disease-2019. A total of 348 samples from 174 patients were tested by RT-PCR assays. Among 174 patients with symptoms, 63 (36%) were SARS-CoV-2 positive in NPS using the optimized home-brew PCR. Of these 63 patients, 61 (98%) were also positive in saliva. An additional positive SARS-CoV-2 saliva was detected in a patient with pneumonia. Kappa Cohen's coefficient agreement between NPS and saliva was 0.96 (95% confidence interval [CI], 0.90-0.99). Median Ct values in NPS versus saliva were 18.88 (interquartile range [IQR], 15.60-23.58; range, 11.97-38.10) versus 26.10 (IQR, 22.75-30.06; range, 13.78-39.22), respectively (p < .0001). The optimized home-brew RT-PCR demonstrated higher analytical and clinical sensitivity compared with the commercial RT-PCR assay. A high sensitivity (98%) and agreement (kappa 0.96) in saliva samples compared to NPS was demonstrated when using an optimized home-brew PCR even when the viral load in saliva was lower than in NPS. This noninvasive sample is easy to collect, requires less consumable and avoids discomfort to patients. Importantly, self-collection of saliva can diminish exposure to healthcare personnel.