Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1097/CCE.0000000000000320

http://scihub22266oqcxt.onion/10.1097/CCE.0000000000000320
suck pdf from google scholar
33458687!7803667!33458687
unlimited free pdf from europmc33458687    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33458687      Crit+Care+Explor 2021 ; 3 (1): e0320
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Presence of Spontaneous Echo Contrast on Point-of-Care Vascular Ultrasound and the Development of Major Clotting Events in Coronavirus Disease 2019 Patients #MMPMID33458687
  • Connor-Schuler R; Daniels L; Coleman C; Harris D; Herbst N; Fiza B
  • Crit Care Explor 2021[Jan]; 3 (1): e0320 PMID33458687show ga
  • The presence of spontaneous echo contrast on ultrasonography is a predisposition to increased thromboembolic risk. The purpose of this study was to assess for the prevalence and consequences of spontaneous echo contrast on point-of-care vascular ultrasound in coronavirus disease 2019. DESIGN SETTING AND PATIENTS: This was a retrospective cohort study of 39 adult patients admitted to the ICU with a confirmed coronavirus disease 2019 diagnosis at a large tertiary-care academic medical center. Patients were included if they had undergone a vascular ultrasound examination during their ICU admission. Overall, 48 venous ultrasound studies among the 39 patients were reviewed in blinded fashion by two reviewers for the presence of venous spontaneous echo contrast, and charts were analyzed for laboratory data and outcomes. MEASUREMENTS AND MAIN RESULTS S: pontaneous echo contrast correlated with serum viscosity (mean values of 2.64, 2.54, and 2.04 cP for dense spontaneous echo contrast, spontaneous echo contrast , and no spontaneous echo contrast, respectively, with a p value of 0.0056 for spontaneous echo contrast compared with negative spontaneous echo contrast) and hyperfibrinogenemia (mean values of 726.6, 668.5, and 566.6 mg/dL for dense spontaneous echo contrast, positive spontaneous echo contrast, and negative spontaneous echo contrast, respectively, with a p value of 0.0045 for dense spontaneous echo contrast compared with negative spontaneous echo contrast). About 36% of patients with dense spontaneous echo contrast and 33% of individuals with positive spontaneous echo contrast experienced significant clotting events compared with 17% of those with negative spontaneous echo contrast. A total of 19% of patients with spontaneous echo contrast suffered a cardiac arrest following a major clotting event, and there were no cardiac arrests from clotting events in the negative spontaneous echo contrast group. There was no association with the presence of spontaneous echo contrast and right or left cardiac function or other laboratory values such as d-dimer, external thromboelastometry - maximum lysis, platelet counts, C-reactive protein, or interleukin-6. CONCLUSIONS: Point-of-care venous ultrasonography is easily performed and reliably interpreted for visualization of spontaneous echo contrast. The presence of spontaneous echo contrast in patients with coronavirus disease 2019 is associated with hyperviscosity and increased rates of thrombotic events and complications.
  • ä


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box