Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Diagn+Microbiol+Infect+Dis 2021 ; 99 (3): 115260 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Evaluation of the BioFire(R) COVID-19 test and Respiratory Panel 2 1 for rapid identification of SARS-CoV-2 in nasopharyngeal swab samples #MMPMID33340934
Eckbo EJ; Locher K; Caza M; Li L; Lavergne V; Charles M
Diagn Microbiol Infect Dis 2021[Mar]; 99 (3): 115260 PMID33340934show ga
The BioFire(R) COVID-19 Test and Respiratory Panel 2.1 (RP2.1) are rapid, fully automated assays for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in nasopharyngeal swabs. In the case of the RP2.1, an additional 21 viral and bacterial pathogens can be detected. Both tests have received emergency use authorization from the U.S. Food & Drug Administration and Interim Order authorization from Health Canada for use in clinical laboratories. We evaluated the performance characteristics of these tests in comparison to a laboratory-developed real-time PCR assay targeting the viral RNA-dependent RNA polymerase and E genes. A total of 78 tests were performed using the BioFire COVID-19 Test, including 30 clinical specimens and 48 tests in a limit of detection study; 57 tests were performed using the RP2.1 for evaluation of SARS-CoV-2 detection, including 30 clinical specimens and 27 tests for limit of detection. Results showed 100% concordance between the BioFire assays and the laboratory-developed test for all clinical samples tested, and acceptable performance of both BioFire assays at their stated limits of detection. Conclusively, the BioFire COVID-19 Test and RP2.1 are highly sensitive assays that can be effectively used in the clinical laboratory for rapid SARS-CoV-2 testing.