Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 278.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 312.4 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 312.4 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Medicine+(Baltimore) 2020 ; 99 (49): e23160 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Successful treatment of a critically ill patient with acute respiratory distress syndrome from COVID-19 using mechanical ventilation strategy with low levels of positive end-expiratory pressure: A CARE-compliant case report #MMPMID33285690
Guo WG; Fang B; Xian YS; Yu ZH; Zhou LX
Medicine (Baltimore) 2020[Dec]; 99 (49): e23160 PMID33285690show ga
INTRODUCTION: Acute respiratory distress syndrome (ARDS) secondary to COVID-19 is different from the ARDS caused by other infections. Conventional mechanical ventilation strategies using high levels of PEEP may not be beneficial and can even be harmful to patient with ARDS from COVID-19. So the ventilation strategies should be adjusted in order to improve the pulmonary ventilation function and oxygenation status, and outcomes of the patient. PATIENT CONCERNS: Herein, we present a 76-year-old male patient with ARDS secondary to COVID-19. We describe our experience with mechanical ventilation strategy and the changes in respiratory mechanics in the patient during treatment. DIAGNOSIS: The patient had tested positive for coronavirus (COVID-19) in nucleic acid test. Chest CT showed multiple ground glass shadows in both lungs. INTERVENTIONS: The patient received mechanical ventilation with low tidal volume and low PEEP. OUTCOMES: After treatment, the patients condition, as well as oxygenation status was improved, and he tested negative for the coronavirus several times. CONCLUSION: This case demonstrated that the low tidal volume with low levels of PEEP ventilation strategy may be more suitable for ARDS from COVID-19.