Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Virology 2021 ; 553 (ä): 154-156 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Analytical and clinical comparison of Viasure (CerTest Biotec) and 2019-nCoV CDC (IDT) RT-qPCR kits for SARS-CoV2 diagnosis #MMPMID33278737
Freire-Paspuel B; Vega-Marino P; Velez A; Cruz M; Perez F; Garcia-Bereguiain MA
Virology 2021[Jan]; 553 (ä): 154-156 PMID33278737show ga
BACKGROUND: Several RT-qPCR kits are available for SARS-CoV-2 diagnosis, some of them with Emergency Use Authorization (EUA) by FDA, but most of them lacking of proper evaluation studies due to covid19 emergency. OBJECTIVE: We evaluated Viasure RT-qPCR kit (CerTest Biotec, Spain) for SARS-CoV-2 diagnosis using FDA EUA 2019-nCoV CDC kit (IDT, USA) as a gold standard. RESULTS: Although we found the lack of RNA quality control probe as the main limitation for the Viasure kit, the sensitivity was 91.9% and the specificity was 100%. The limit of detection (LOD) was 2000 copies/mL and 1000 copies/mL for Viasure and IDT kits, respectively. CONCLUSIONS: Viasure RT-qPCR kit is a reliable tool for SARS-CoV-2 diagnosis but improvement of an alternative RT-qPCR reaction for RNA extraction quality control as RNaseP is recommended.