Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1136/emermed-2020-209972

http://scihub22266oqcxt.onion/10.1136/emermed-2020-209972
suck pdf from google scholar
33277345!ä!33277345

suck abstract from ncbi

pmid33277345      Emerg+Med+J 2021 ; 38 (3): 220-223
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Evaluating cross contamination on a shared ventilator #MMPMID33277345
  • Doukas DJ; Paladino L; Hanuscin C; McMahon J; Quale J; Bhatt I; Eason J; Silverberg M
  • Emerg Med J 2021[Mar]; 38 (3): 220-223 PMID33277345show ga
  • BACKGROUND: Disasters have the potential to cause critical shortages of life-saving equipment. It has been postulated that during patient surge, multiple individuals could be maintained on a single ventilator. This was supported by a previous trial that showed one ventilator could support four sheep. The goal of our study is to investigate if cross contamination of pathological agents occurs between individuals on a shared ventilator with strategically placed antimicrobial filters. METHODS: A multipatient ventilator circuit was assembled using four sterile, parallel standard tubing circuits attached to four 2 L anaesthesia bags, each representing a simulated patient. Each 'patient' was attached to a Heat and Moisture Exchange filter. An additional bacterial/viral filter was attached to each expiratory limb. 'Patient-Lung' number 1 was inoculated with an isolate of Serratia marcescens, and the circuit was run for 24 hours. Each 'lung' and three points in the expiratory limb tubing were washed with broth and cultured. All cultures were incubated for 48 hours with subcultures performed at 24 hours. RESULTS: Washed cultures of patient 2, 3 and 4 failed to demonstrate growth of S. marcescens. Cultures of the distal expiratory tubing, expiratory limb connector and expiratory limb prefilter tubing yielded no growth of S. marcescens at 24 or 48 hours. CONCLUSION: Based on this circuit configuration, it is plausible to maintain four individuals on a single ventilator for 24 hours without fear of cross contamination.
  • |*Equipment Contamination[MESH]
  • |*Ventilators, Mechanical[MESH]
  • |Cross Infection/*transmission[MESH]
  • |Equipment Design[MESH]
  • |Filtration/*instrumentation[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box