Quantification of aerosol generation during cataract surgery #MMPMID33229968
Noureddin GS; Iovieno A; Eslami M; Weaver T; Meadows H; Yeung SN
J Cataract Refract Surg 2021[Aug]; 47 (8): 1071-1074 PMID33229968show ga
PURPOSE: To determine whether phacoemulsification cataract surgery is an aerosol-generating medical procedure (AGMP) and, therefore, to help determine the personal protective equipment required by healthcare providers in the era of the COVID-19. SETTING: The Surgery, Teaching and Research Wet Lab of the Department of Ophthalmology and Visual Sciences, Faculty of Medicine, UBC. DESIGN: Laboratory-based simulation. METHODS: Phacoemulsification cataract surgery was performed on porcine eyes. At a fixed distance, a DRX Aerosol Monitor 8534 (DustTrak) was used to measure particulate matter (PM) mass fractions for each of 3 particle sizes, PM1, PM2.5, and PM4 (in microns), every 2 seconds during surgery and for 1 minute after. The main outcome measure was an increase in the mass fraction of aerosolized particles of various sizes. RESULTS: There was no significant aerosolization of particles during cataract surgery for both the 2.4 and 2.75 mm wound sizes. CONCLUSIONS: Phacoemulsification cataract surgery was not found to be an AGMP. In the midst of the COVID-19 pandemic, ophthalmologists can continue to use droplet precautions while performing this surgery.