Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1016/j.jhin.2020.10.024

http://scihub22266oqcxt.onion/10.1016/j.jhin.2020.10.024
suck pdf from google scholar
33157170!7609237!33157170
unlimited free pdf from europmc33157170    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 298.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33157170      J+Hosp+Infect 2021 ; 108 (ä): 113-119
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Decontamination of filtering facepiece respirators using a low-temperature-steam-2%-formaldehyde sterilization process during a pandemic: a safe alternative for re-use #MMPMID33157170
  • Garcia-Haro M; Bischofberger Valdes C; Vicente-Guijarro J; Diaz-Agero Perez C; Fabregate-Fuente M; Moreno-Nunez P; Aranaz-Andres JM
  • J Hosp Infect 2021[Feb]; 108 (ä): 113-119 PMID33157170show ga
  • BACKGROUND: The coronavirus disease 2019 pandemic has caused problems with respirator supplies. Re-use may minimize the impact of the shortage, but requires the availability of an efficient and safe decontamination method. AIM: To determine whether low-temperature-steam-2%-formaldehyde (LTSF) sterilization is effective, preserves the properties of filtering facepiece (FFP) respirators and allows safe re-use. METHODS: Fourteen unused FFP2, FFP3 and N95 respirator models were subjected to two cycles of decontamination cycles. After the second cycle, each model was inspected visually and accumulated residual formaldehyde levels were analysed according to EN 14180. After one and two decontamination cycles, the fit factor (FF) of each model was tested, and penetration tests with sodium chloride aerosols were performed on five models. FINDINGS: Decontamination physically altered three of the 14 models. All of the residual formaldehyde values were below the permissible threshold. Irregular decreases and increases in FF were observed after each decontamination cycle. In the sodium chloride aerosol penetration test, three models obtained equivalent or superior results to those of the FFP classification with which they were marketed, both at baseline and after one and two cycles of decontamination, and two models had lower filtering capacity. CONCLUSION: One and two decontamination cycles using LTSF did not alter the structure of most (11/14) respirators tested, and did not degrade the fit or filtration capacity of any of the analysed respirators. The residual formaldehyde levels complied with EN 14180. This reprocessing method could be used in times of shortage of personal protective equipment.
  • |Adult[MESH]
  • |Aerosols/adverse effects[MESH]
  • |COVID-19/diagnosis/epidemiology/prevention & control/virology[MESH]
  • |Decontamination/*methods[MESH]
  • |Equipment Reuse[MESH]
  • |Formaldehyde/analysis/*pharmacology[MESH]
  • |Humans[MESH]
  • |Male[MESH]
  • |Masks/trends/virology[MESH]
  • |Personal Protective Equipment/supply & distribution[MESH]
  • |Respiratory Protective Devices/supply & distribution/*virology[MESH]
  • |SARS-CoV-2/genetics[MESH]
  • |Sodium Chloride/analysis[MESH]
  • |Steam/adverse effects[MESH]
  • |Sterilization/*methods[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box