Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 235.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 269.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Clin+Microbiol 2021 ; 59 (2): ä Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
A Multiplex Microsphere IgG Assay for SARS-CoV-2 Using ACE2-Mediated Inhibition as a Surrogate for Neutralization #MMPMID33139422
J Clin Microbiol 2021[Jan]; 59 (2): ä PMID33139422show ga
The coronavirus disease 2019 (COVID-19) pandemic has highlighted the challenges inherent to the serological detection of a novel pathogen such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Serological tests can be used diagnostically and for surveillance, but their usefulness depends on their throughput, sensitivity, and specificity. Here, we describe a multiplex fluorescent microsphere-based assay, 3Flex, that can detect antibodies to three major SARS-CoV-2 antigens-spike (S) protein, the spike ACE2 receptor-binding domain (RBD), and nucleocapsid (NP). Specificity was assessed using 213 prepandemic samples. Sensitivity was measured and compared to that of the Abbott Architect SARS-CoV-2 IgG assay using serum samples from 125 unique patients equally binned (n = 25) into 5 time intervals (=5, 6 to 10, 11 to 15, 16 to 20, and >/=21 days from symptom onset). With samples obtained at =5 days from symptom onset, the 3Flex assay was more sensitive (48.0% versus 32.0%), but the two assays performed comparably using serum obtained >/=21 days from symptom onset. A larger collection (n = 534) of discarded sera was profiled from patients (n = 140) whose COVID-19 course was characterized through chart review. This revealed the relative rise, peak (S, 23.8; RBD, 23.6; NP, 16.7 [in days from symptom onset]), and decline of the antibody response. Considerable interperson variation was observed with a subset of extensively sampled intensive care unit (ICU) patients. Using soluble ACE2, inhibition of antibody binding was demonstrated for S and RBD, and not for NP. Taking the data together, this study described the performance of an assay built on a flexible and high-throughput serological platform that proved adaptable to the emergence of a novel infectious agent.