Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1128/JCM.02257-20

http://scihub22266oqcxt.onion/10.1128/JCM.02257-20
suck pdf from google scholar
33139419!8111143!33139419
unlimited free pdf from europmc33139419    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 233.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 267.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 300.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 300.79999999999995 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid33139419      J+Clin+Microbiol 2021 ; 59 (2): ä
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Comparative Performance of Five Commercially Available Serologic Assays To Detect Antibodies to SARS-CoV-2 and Identify Individuals with High Neutralizing Titers #MMPMID33139419
  • Patel EU; Bloch EM; Clarke W; Hsieh YH; Boon D; Eby Y; Fernandez RE; Baker OR; Keruly M; Kirby CS; Klock E; Littlefield K; Miller J; Schmidt HA; Sullivan P; Piwowar-Manning E; Shrestha R; Redd AD; Rothman RE; Sullivan D; Shoham S; Casadevall A; Quinn TC; Pekosz A; Tobian AAR; Laeyendecker O
  • J Clin Microbiol 2021[Jan]; 59 (2): ä PMID33139419show ga
  • Accurate serological assays to detect antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are needed to characterize the epidemiology of SARS-CoV-2 infection and identify potential candidates for coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) donation. This study compared the performances of commercial enzyme immunoassays (EIAs) with respect to detection of IgG or total antibodies to SARS-CoV-2 and neutralizing antibodies (nAbs). The diagnostic accuracy of five commercially available EIAs (Abbott, Euroimmun, EDI, ImmunoDiagnostics, and Roche) for detection of IgG or total antibodies to SARS-CoV-2 was evaluated using cross-sectional samples from potential CCP donors who had prior molecular confirmation of SARS-CoV-2 infection (n = 214) and samples from prepandemic emergency department patients without SARS-CoV-2 infection (n = 1,099). Of the 214 potential CCP donors, all were sampled >14 days since symptom onset and only a minority (n = 16 [7.5%]) had been hospitalized due to COVID-19; 140 potential CCP donors were tested by all five EIAs and a microneutralization assay. Performed according to the protocols of the manufacturers to detect IgG or total antibodies to SARS-CoV-2, the sensitivity of each EIA ranged from 76.4% to 93.9%, and the specificity of each EIA ranged from 87.0% to 99.6%. Using a nAb titer cutoff value of >/=160 as the reference representing a positive test result (n = 140 CCP donors), the empirical area under the receiver operating curve for each EIA ranged from 0.66 (Roche) to 0.90 (Euroimmun). Commercial EIAs with high diagnostic accuracy to detect SARS-CoV-2 antibodies did not necessarily have high diagnostic accuracy to detect high nAb titers. Some but not all commercial EIAs may be useful in the identification of individuals with high nAb titers among convalescent individuals.
  • |Antibodies, Neutralizing/*blood[MESH]
  • |Antibodies, Viral/*blood[MESH]
  • |COVID-19 Serological Testing/*methods[MESH]
  • |COVID-19/blood/*diagnosis[MESH]
  • |Cross-Sectional Studies[MESH]
  • |Humans[MESH]
  • |Immune Sera/immunology[MESH]
  • |Immunoenzyme Techniques[MESH]
  • |Immunoglobulin G/blood[MESH]
  • |Neutralization Tests[MESH]
  • |SARS-CoV-2/immunology/*isolation & purification[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box