Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1002/ehf2.13033

http://scihub22266oqcxt.onion/10.1002/ehf2.13033
suck pdf from google scholar
32965779!7537224!32965779
unlimited free pdf from europmc32965779    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi

pmid32965779      ESC+Heart+Fail 2020 ; 7 (6): 4361-4366
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • A rise in left atrial pressure detected by the V-LAP system for patients with heart failure during the coronavirus disease 2019 pandemic #MMPMID32965779
  • Perl L; Ben Avraham B; Vaknin-Assa H; Ben Gal T; Kornowski R
  • ESC Heart Fail 2020[Dec]; 7 (6): 4361-4366 PMID32965779show ga
  • During the coronavirus disease 2019 (COVID-19) pandemic, many patients refrained from inpatient medical care. For those inflicted with heart failure (HF), the risk of repeat hospitalizations is particularly high in case of infection. This presents an important opportunity for remote monitoring of haemodynamic data for these patients, in order to detect and treat accordingly. The aim of the present case is to report of the first measurements of a novel wireless left atrial pressure (LAP) monitoring system, the V-LAP (Vectorious Medical Technologies, Ltd), during the COVID-19 pandemic. The V-LAP Left Atrium Monitoring systEm for Patients With Chronic sysTOlic & Diastolic Congestive heart Failure (VECTOR-HF) is a first-in-man clinical study assessing the safety and feasibility of the V-LAP monitoring system. Our first patient, a 59-year-old man with severe ischaemic cardiomyopathy (left ventricular ejection fraction -30%) was enrolled prior to the COVID-19 outbreak. As per protocol, both the patient and the medical team were blinded to the results in the first 3 months after implantation. We were able to witness the LAP during the pandemic, as the patient remained undertreated, demonstrating a gradual increase from a mean pressure of 6.56 to 19.4 mmHg, as well as prominent V waves, before the data became available to the medical team and the patient was treated accordingly. Thereafter, pressures have returned to low values. This case demonstrated the feasibility of remote monitoring of LAP using the V-LAP system, as well as the potential benefit of remote care of HF patients.
  • ?


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box