Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Korean+Med+Sci 2020 ; 35 (31): e287 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Viral Load Kinetics of SARS-CoV-2 Infection in Saliva in Korean Patients: a Prospective Multi-center Comparative Study #MMPMID32776725
Kim SE; Lee JY; Lee A; Kim S; Park KH; Jung SI; Kang SJ; Oh TH; Kim UJ; Lee SY; Kee SJ; Jang HC
J Korean Med Sci 2020[Aug]; 35 (31): e287 PMID32776725show ga
BACKGROUND: This study was performed to compare the viral load and kinetics of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) in saliva with those in standard nasopharyngeal/oropharyngeal (NP/OP) swabs. METHODS: Fifteen patients with SARS-CoV-2 infection from four hospitals were prospectively enrolled and matched samples of nasopharyngeal/oropharyngeal swabs and saliva were collected at Day 1 of admission and every other day till consequently negative for two times. Real-time reverse transcription polymerase chain reaction (rRT-PCR) was performed to detect the envelope (E) and RNA-dependent RNA polymerase (RdRP) genes. RESULTS: The cycle threshold values of saliva were comparable to those of NP/OP swabs overall (P = 0.720, Mann-Whitney U test). However, the overall sensitivity of rRT-PCR using saliva was 64% (34/53), which is lower than the 77% (41/53) using NP/OP swabs. The sensitivity of rRT-PCR using saliva was especially lower in early stage of symptom onset (1-5 days; 8/15; 53%) and in patients who did not have sputum (12/22; 55%). CONCLUSION: Saliva sample itself is not appropriate for initial diagnosis of coronavirus disease 2019 (COVID-19) to replace NP/OP swabs, especially for the person who does not produce sputum. COVID-19 cannot be excluded when the test using saliva is negative, and it is necessary to retest using NP/OP swabs.