Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 J+Appl+Lab+Med 2020 ; 5 (6): 1307-1312 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Comparison of a Point-of-Care Assay and a High-Complexity Assay for Detection of SARS-CoV-2 RNA #MMPMID32761092
J Appl Lab Med 2020[Nov]; 5 (6): 1307-1312 PMID32761092show ga
BACKGROUND: Numerous nucleic acid amplification assays utilizing different target genes of the SARS-CoV-2 genome have received emergency use authorization (EUA) by the United States Food and Drug Administration (FDA). Limited data are available comparing the test performance characteristics of these assays. METHODS: A diagnostic comparison study was performed to evaluate the performance of the Cepheid Xpert Xpress SARS-CoV-2 assay compared to the Hologic Panther Fusion SARS-CoV-2 assay using clinical nasopharyngeal specimens. Agreement between the two assays was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: A total of 104 (54 positive and 50 negative) clinical nasopharyngeal samples were tested by both assays. Using the Panther Fusion as a reference standard, the Xpert demonstrated an overall agreement of 99.0% [95% confidence interval (CI): 94.8-100], positive percent agreement of 98.1% (95% CI: 90.1-100), and a negative percent agreement of 100% (95% CI: 94.2-100). The kappa coefficient was 0.98 (95% CI: 0.94-1.0). One sample positive by the Panther Fusion with a cycle threshold (Ct) of 38.6 was found to be reproducibly negative by the Xpert assay. CONCLUSIONS: The Cepheid Xpert Xpress SARS-CoV-2 assay provides test performance comparable to the Hologic Panther Fusion SARS-CoV-2 assay while offering laboratories rapid, on-demand testing capacity.