Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1111/acem.14048

http://scihub22266oqcxt.onion/10.1111/acem.14048
suck pdf from google scholar
32542934!7323136!32542934
unlimited free pdf from europmc32542934    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 209.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 243.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid32542934      Acad+Emerg+Med 2020 ; 27 (8): 653-670
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Diagnosing COVID-19 in the Emergency Department: A Scoping Review of Clinical Examinations, Laboratory Tests, Imaging Accuracy, and Biases #MMPMID32542934
  • Carpenter CR; Mudd PA; West CP; Wilber E; Wilber ST
  • Acad Emerg Med 2020[Aug]; 27 (8): 653-670 PMID32542934show ga
  • OBJECTIVE: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged as a global pandemic in early 2020 with rapidly evolving approaches to diagnosing the clinical illness called coronavirus disease (COVID-19). The primary objective of this scoping review is to synthesize current research of the diagnostic accuracy of history, physical examination, routine laboratory tests, real-time reverse transcription-polymerase chain reaction (rRT-PCR), immunology tests, and computed tomography (CT) for the emergency department (ED) diagnosis of COVID-19. Secondary objectives included a synopsis of diagnostic biases likely with current COVID-19 research as well as corresponding implications of false-negative and false-positive results for clinicians and investigators. METHODS: A Preferred Reporting Items for Systematic Reviews and Meta-Analyses-Scoping Review (PRISMA-ScR)-adherent synthesis of COVID-19 diagnostic accuracy through May 5, 2020, was conducted. The search strategy was designed by a medical librarian and included studies indexed by PubMed and Embase since January 2020. RESULTS: A total of 1,907 citations were screened for relevance. Patients without COVID-19 are rarely reported, so specificity and likelihood ratios were generally unavailable. Fever is the most common finding, while hyposmia and hypogeusia appear useful to rule in COVID-19. Cough is not consistently present. Lymphopenia is the mostly commonly reported laboratory abnormality and occurs in over 50% of COVID-19 patients. rRT-PCR is currently considered the COVID-19 criterion standard for most diagnostic studies, but a single test sensitivity ranges from 60% to 78%. Multiple reasons for false-negatives rRT-PCR exist, including sample site tested and disease stage during which sample was obtained. CT may increase COVID-19 sensitivity in conjunction with rRT-PCR, but guidelines for imaging patients most likely to benefit are emerging. IgM and IgG serology levels are undetectable in the first week of COVID-19, but sensitivity (range = 82% to 100%) and specificity (range = 87% to 100%) are promising. Whether detectable COVID-19 antibodies correspond to immunity remains unanswered. Current studies do not adhere to accepted diagnostic accuracy reporting standards and likely report significantly biased results if the same tests were to be applied to general ED populations with suspected COVID-19. CONCLUSIONS: With the exception of fever and disorders of smell/taste, history and physical examination findings are unhelpful to distinguish COVID-19 from other infectious conditions that mimic SARS-CoV-2 like influenza. Routine laboratory tests are also nondiagnostic, although lymphopenia is a common finding and other abnormalities may predict severe disease. Although rRT-PCR is the current criterion standard, more inclusive consensus-based criteria will likely emerge because of the high false-negative rate of PCR tests. The role of serology and CT in ED assessments remains undefined.
  • |*Emergency Service, Hospital[MESH]
  • |Adult[MESH]
  • |COVID-19 Testing/*statistics & numerical data[MESH]
  • |COVID-19/*diagnosis[MESH]
  • |Diagnostic Tests, Routine[MESH]
  • |Female[MESH]
  • |Humans[MESH]
  • |Pandemics/statistics & numerical data[MESH]
  • |Physical Examination/statistics & numerical data[MESH]
  • |SARS-CoV-2/*isolation & purification[MESH]