Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1186/s13075-020-02211-1

http://scihub22266oqcxt.onion/10.1186/s13075-020-02211-1
suck pdf from google scholar
32475347!7261520!32475347
unlimited free pdf from europmc32475347    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 211.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 245.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid32475347      Arthritis+Res+Ther 2020 ; 22 (1): 125
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • Measurement of hydroxychloroquine in blood from SLE patients using LC-HRMS-evaluation of whole blood, plasma, and serum as sample matrices #MMPMID32475347
  • Carlsson H; Hjorton K; Abujrais S; Ronnblom L; Akerfeldt T; Kultima K
  • Arthritis Res Ther 2020[Jun]; 22 (1): 125 PMID32475347show ga
  • BACKGROUND: Hydroxychloroquine (HCQ) is the standard of care in the treatment of systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), and other inflammatory rheumatic diseases and potentially for the treatment in COVID-19 patients. Determination of HCQ for therapeutic drug monitoring (TDM) can be performed in whole blood (WB), serum, and plasma. Direct comparisons of WB, serum, and plasma levels of HCQ in patients with SLE have not previously been reported. We describe a method for the determination of HCQ in human blood using liquid chromatography-high-resolution mass spectrometry (LC-HRMS) and compare the suitability of the three sample matrices. METHODS: A method for the determination of HCQ in human blood using LC-HRMS was developed, validated, and applied for the determination of HCQ levels in WB, serum, and plasma from 26 SLE patients. The reproducibility of the method, in the three matrices, was evaluated using quality control samples and repeated preparations and measurements of patient samples. The performance of the developed method for HCQ measurement in serum was further evaluated by comparison with two previously reported extraction methods. RESULTS: The performance of the presented method demonstrated high accuracy and precision. A large range of HCQ concentrations was observed for the SLE patients in all three matrices (WB, serum, and plasma). The mean levels in WB were approximately two-fold the levels in serum and plasma (813 ng/mL compared to 436 ng/mL and 362 ng/mL, respectively). Spiked quality controls showed high reproducibility for all matrices (coefficient of variation, CV, approx. 5%), whereas in patient samples, equally high-precision was only found using WB as the matrix (CV 3%). The CV for serum and plasma was 14% and 39%, respectively. Two alternative methods applied to serum samples did not demonstrate improved precision. CONCLUSIONS: A LC-HRMS method for the measurement of HCQ in human blood was developed and validated. Whole blood was found to be the superior sample matrix in terms of sample reproducibility. Thus, whole blood samples should be used for HCQ analysis when patients are monitored for HCQ treatment effects. The assay is in clinical use to monitor levels of HCQ in patients.
  • |*Betacoronavirus[MESH]
  • |*Coronavirus Infections/blood/drug therapy[MESH]
  • |*Pandemics[MESH]
  • |*Pneumonia, Viral/blood/drug therapy[MESH]
  • |Adult[MESH]
  • |Aged[MESH]
  • |COVID-19[MESH]
  • |Chromatography, Liquid/methods/standards[MESH]
  • |Drug Monitoring/methods/*standards[MESH]
  • |Female[MESH]
  • |Humans[MESH]
  • |Hydroxychloroquine/*blood/therapeutic use[MESH]
  • |Lupus Erythematosus, Systemic/*blood/*drug therapy[MESH]
  • |Male[MESH]
  • |Mass Spectrometry/methods/standards[MESH]
  • |Middle Aged[MESH]
  • |Plasma[MESH]
  • |SARS-CoV-2[MESH]
  • |Serum[MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box