Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534 Ann+Transl+Med 2020 ; 8 (7): 450 Nephropedia Template TP
gab.com Text
Twit Text FOAVip
Twit Text #
English Wikipedia
Deep learning for detecting corona virus disease 2019 (COVID-19) on high-resolution computed tomography: a pilot study #MMPMID32395494
Yang S; Jiang L; Cao Z; Wang L; Cao J; Feng R; Zhang Z; Xue X; Shi Y; Shan F
Ann Transl Med 2020[Apr]; 8 (7): 450 PMID32395494show ga
BACKGROUND: To evaluate the diagnostic efficacy of Densely Connected Convolutional Networks (DenseNet) for detection of COVID-19 features on high resolution computed tomography (HRCT). METHODS: The Ethic Committee of our institution approved the protocol of this study and waived the requirement for patient informed consent. Two hundreds and ninety-five patients were enrolled in this study (healthy person: 149; COVID-19 patients: 146), which were divided into three separate non-overlapping cohorts (training set, n=135, healthy person, n=69, patients, n=66; validation set, n=20, healthy person, n=10, patients, n=10; test set, n=140, healthy person, n=70, patients, n=70). The DenseNet was trained and tested to classify the images as having manifestation of COVID-19 or as healthy. A radiologist also blindly evaluated all the test images and rechecked the misdiagnosed cases by DenseNet. Receiver operating characteristic curves (ROC) and areas under the curve (AUCs) were used to assess the model performance. The sensitivity, specificity and accuracy of DenseNet model and radiologist were also calculated. RESULTS: The DenseNet algorithm model yielded an AUC of 0.99 (95% CI: 0.958-1.0) in the validation set and 0.98 (95% CI: 0.972-0.995) in the test set. The threshold value was selected as 0.8, while for validation and test sets, the accuracies were 95% and 92%, the sensitivities were 100% and 97%, the specificities were 90% and 87%, and the F1 values were 95% and 93%, respectively. The sensitivity of radiologist was 94%, the specificity was 96%, while the accuracy was 95%. CONCLUSIONS: Deep learning (DL) with DenseNet can accurately classify COVID-19 on HRCT with an AUC of 0.98, which can reduce the miss diagnosis rate (combined with radiologists' evaluation) and radiologists' workload.