Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1186/s12968-020-00613-3

http://scihub22266oqcxt.onion/10.1186/s12968-020-00613-3
suck pdf from google scholar
32375896!7204222!32375896
unlimited free pdf from europmc32375896    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 231.6 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534

Deprecated: Implicit conversion from float 265.2 to int loses precision in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 534
pmid32375896      J+Cardiovasc+Magn+Reson 2020 ; 22 (1): 31
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • T(1) mapping performance and measurement repeatability: results from the multi-national T(1) mapping standardization phantom program (T1MES) #MMPMID32375896
  • Captur G; Bhandari A; Bruhl R; Ittermann B; Keenan KE; Yang Y; Eames RJ; Benedetti G; Torlasco C; Ricketts L; Boubertakh R; Fatih N; Greenwood JP; Paulis LEM; Lawton CB; Bucciarelli-Ducci C; Lamb HJ; Steeds R; Leung SW; Berry C; Valentin S; Flett A; de Lange C; DeCobelli F; Viallon M; Croisille P; Higgins DM; Greiser A; Pang W; Hamilton-Craig C; Strugnell WE; Dresselaers T; Barison A; Dawson D; Taylor AJ; Mongeon FP; Plein S; Messroghli D; Al-Mallah M; Grieve SM; Lombardi M; Jang J; Salerno M; Chaturvedi N; Kellman P; Bluemke DA; Nezafat R; Gatehouse P; Moon JC
  • J Cardiovasc Magn Reson 2020[May]; 22 (1): 31 PMID32375896show ga
  • BACKGROUND: The T(1) Mapping and Extracellular volume (ECV) Standardization (T1MES) program explored T(1) mapping quality assurance using a purpose-developed phantom with Food and Drug Administration (FDA) and Conformite Europeenne (CE) regulatory clearance. We report T(1) measurement repeatability across centers describing sequence, magnet, and vendor performance. METHODS: Phantoms batch-manufactured in August 2015 underwent 2 years of structural imaging, B(0) and B(1), and "reference" slow T(1) testing. Temperature dependency was evaluated by the United States National Institute of Standards and Technology and by the German Physikalisch-Technische Bundesanstalt. Center-specific T(1) mapping repeatability (maximum one scan per week to minimum one per quarter year) was assessed over mean 358 (maximum 1161) days on 34 1.5 T and 22 3 T magnets using multiple T(1) mapping sequences. Image and temperature data were analyzed semi-automatically. Repeatability of serial T(1) was evaluated in terms of coefficient of variation (CoV), and linear mixed models were constructed to study the interplay of some of the known sources of T(1) variation. RESULTS: Over 2 years, phantom gel integrity remained intact (no rips/tears), B(0) and B(1) homogenous, and "reference" T(1) stable compared to baseline (% change at 1.5 T, 1.95 +/- 1.39%; 3 T, 2.22 +/- 1.44%). Per degrees Celsius, 1.5 T, T(1) (MOLLI 5s(3s)3s) increased by 11.4 ms in long native blood tubes and decreased by 1.2 ms in short post-contrast myocardium tubes. Agreement of estimated T(1) times with "reference" T(1) was similar across Siemens and Philips CMR systems at both field strengths (adjusted R(2) ranges for both field strengths, 0.99-1.00). Over 1 year, many 1.5 T and 3 T sequences/magnets were repeatable with mean CoVs < 1 and 2% respectively. Repeatability was narrower for 1.5 T over 3 T. Within T1MES repeatability for native T(1) was narrow for several sequences, for example, at 1.5 T, Siemens MOLLI 5s(3s)3s prototype number 448B (mean CoV = 0.27%) and Philips modified Look-Locker inversion recovery (MOLLI) 3s(3s)5s (CoV 0.54%), and at 3 T, Philips MOLLI 3b(3s)5b (CoV 0.33%) and Siemens shortened MOLLI (ShMOLLI) prototype 780C (CoV 0.69%). After adjusting for temperature and field strength, it was found that the T(1) mapping sequence and scanner software version (both P < 0.001 at 1.5 T and 3 T), and to a lesser extent the scanner model (P = 0.011, 1.5 T only), had the greatest influence on T(1) across multiple centers. CONCLUSION: The T1MES CE/FDA approved phantom is a robust quality assurance device. In a multi-center setting, T(1) mapping had performance differences between field strengths, sequences, scanner software versions, and manufacturers. However, several specific combinations of field strength, sequence, and scanner are highly repeatable, and thus, have potential to provide standardized assessment of T(1) times for clinical use, although temperature correction is required for native T(1) tubes at least.