Bioabsorbable metal screws in traumatology: A promising innovation
#MMPMID29644307
Biber R
; Pauser J
; Brem M
; Bail HJ
Trauma Case Rep
2017[Apr]; 8
(ä): 11-15
PMID29644307
show ga
MAGNEZIX® CS (Syntellix AG, Hanover, Germany) is a bioabsorbable compression
screw made of a magnesium alloy (MgYREZr). Currently there are only two clinical
studies reporting on a limited number of elective patients who received this
screw in a hallux valgus operation. We applied MAGNEZIX® CS for fixation of
distal fibular fracture in a trauma patient who had sustained a bimalleolar
fracture type AO 44-B2.3. Clinical course was uneventful, fracture healing
occurred within three months. Follow-up X-rays showed a radiolucent area around
the implant for some months, yet this radiolucent area had disappeared in the
17-months follow-up X-ray.