Use my Search Websuite to scan PubMed, PMCentral, Journal Hosts and Journal Archives, FullText.
Kick-your-searchterm to multiple Engines kick-your-query now !>
A dictionary by aggregated review articles of nephrology, medicine and the life sciences
Your one-stop-run pathway from word to the immediate pdf of peer-reviewed on-topic knowledge.

suck abstract from ncbi


10.1002/mrm.21073

http://scihub22266oqcxt.onion/10.1002/mrm.21073
suck pdf from google scholar
C4406343!4406343 !17075852
unlimited free pdf from europmc17075852
    free
PDF from PMC    free
html from PMC    free

suck abstract from ncbi


Warning: imagejpeg(C:\Inetpub\vhosts\kidney.de\httpdocs\phplern\17075852 .jpg): Failed to open stream: No such file or directory in C:\Inetpub\vhosts\kidney.de\httpdocs\pget.php on line 117
pmid17075852
      Magn+Reson+Med 2006 ; 56 (6 ): 1274-82
Nephropedia Template TP

gab.com Text

Twit Text FOAVip

Twit Text #

English Wikipedia


  • 9 4T human MRI: preliminary results #MMPMID17075852
  • Vaughan T ; DelaBarre L ; Snyder C ; Tian J ; Akgun C ; Shrivastava D ; Liu W ; Olson C ; Adriany G ; Strupp J ; Andersen P ; Gopinath A ; van de Moortele PF ; Garwood M ; Ugurbil K
  • Magn Reson Med 2006[Dec]; 56 (6 ): 1274-82 PMID17075852 show ga
  • This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T.
  • |*Transducers [MESH]
  • |Burns, Electric/etiology/prevention & control [MESH]
  • |Dizziness/etiology/prevention & control [MESH]
  • |Equipment Design [MESH]
  • |Equipment Failure Analysis [MESH]
  • |Humans [MESH]
  • |Image Enhancement/*instrumentation/methods [MESH]
  • |Magnetic Resonance Imaging/adverse effects/*instrumentation/methods [MESH]
  • |Pilot Projects [MESH]
  • |Radiation Protection/*instrumentation/methods [MESH]


  • DeepDyve
  • Pubget Overpricing
  • suck abstract from ncbi

    Linkout box