Warning: Undefined variable $zfal in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 525
Deprecated: str_replace(): Passing null to parameter #3 ($subject) of type array|string is deprecated in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 525
Warning: Undefined variable $sterm in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 530
free
Warning: Undefined variable $sterm in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 531
free free
English Wikipedia
Nephropedia Template TP (
Twit Text
DeepDyve Pubget Overpricing |
lüll Clinical effectiveness of the Respimat inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices Ram FS; Carvallho CR; White JInt J Chron Obstruct Pulmon Dis 2011[]; 6 (ä): 129-39OBJECTIVES: Medication for the management of chronic obstructive pulmonary disease (COPD) may be delivered by a number of different inhaler devices. This study was undertaken to determine the clinical effectiveness of the Respimat handheld inhaler device compared with other handheld inhaler devices for the delivery of medication in stable COPD. METHODOLOGY: A systematic review of high-quality randomized controlled clinical trials comparing Respimat with other inhaler devices using the same medication was performed. Studies were searched for in the Cochrane Central Register of Controlled Trials as well as other relevant electronic databases. Manufacturers of inhaled COPD medication were also contacted for potential trials. RESULTS: Seven studies of high methodological quality with 3813 participants were included in the review. Three trials used Handihaler as the comparator inhaler, three used a chlorofluorocarbon metered-dose inhaler (CFC-MDI), and one trial used a hydroflouroalkane (HFA)-MDI. When Respimat was compared with Handihaler, the following reported outcomes were not significantly different: trough forced expiratory volume in 1 second (FEV(1)) (weighted mean difference [WMD] 0.01 L; P = 0.14), trough forced vital capacity (FVC) (WMD 0.001 L: P = 0.88), peak FEV(1) (WMD 0.01 L: P = 0.08), peak FVC (WMD 0.01 L: P = 0.55), morning peak expiratory flow rate (PEFR) (WMD 5.06 L/min: P = 0.08), and evening PEFR (WMD 4.39 L/min: P = 0.15). Furthermore, there were no differences when Respimat was compared with Handihaler for risk of exacerbations (relative risk [RR] 0.94: P = 0.81), dry mouth (RR 1.57: P = 0.34), or nasopharyngitis (RR 1.42: P = 0.22). For Respimat compared with CFC-MDI, the only outcome for which data were available for meta-analysis was exacerbations, which were not significantly different (RR 1.20: P = 0.12). In addition, five trials with 2136 patients showed that there was no difference in risk of exacerbations or nasopharyngitis when Respimat was compared with all other handheld inhaler devices (RR 1.18: P = 0.13 and RR 1.33: P = 0.19, respectively). None of the clinical outcome measures reported was significantly different when the same, higher, or lower doses of medication were used in the inhaler devices being compared. Unfortunately, none of the included trials reported mortality as an outcome measure. CONCLUSIONS: Evidence from high-quality trials published to date suggests that the Respimat inhaler does not provide any additional clinical benefit to that provided by other inhaler devices in the management of COPD. Although in vitro studies have reported differences between the Respimat inhaler device and other handheld devices, we found no difference in any clinical outcome measures, including lung function and adverse events. Although recent reports have highlighted concerns of increased mortality with the Respimat inhaler device, none of the included trials reported mortality as an outcome. Only a small number of trials reported data that could be used in this systematic review, and a limited number of studies have been published that compare Respimat with other inhaler devices using the same drug and strength. Therefore, further trials comparing Respimat with other handheld inhaler devices using the same drug and dose are required before firm conclusions can be drawn. The concern with increased mortality with Respimat use should be investigated urgently.|*Metered Dose Inhalers[MESH]|Administration, Inhalation[MESH]|Aerosols[MESH]|Aged[MESH]|Bronchodilator Agents/*administration & dosage/adverse effects[MESH]|Equipment Design[MESH]|Evidence-Based Medicine[MESH]|Female[MESH]|Forced Expiratory Volume[MESH]|Humans[MESH]|Lung/*drug effects/physiopathology[MESH]|Male[MESH]|Middle Aged[MESH]|Peak Expiratory Flow Rate[MESH]|Pulmonary Disease, Chronic Obstructive/*drug therapy/physiopathology[MESH]|Randomized Controlled Trials as Topic[MESH]|Risk Assessment[MESH]|Treatment Outcome[MESH]|Vital Capacity[MESH] |