Warning: Undefined variable $zfal in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 525
Deprecated: str_replace(): Passing null to parameter #3 ($subject) of type array|string is deprecated in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 525
Warning: Undefined variable $sterm in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 530
Warning: Undefined variable $sterm in C:\Inetpub\vhosts\kidney.de\httpdocs\mlpefetch.php on line 531
English Wikipedia
Nephropedia Template TP (
Twit Text
DeepDyve Pubget Overpricing |
lüll Clinical comparison of standard-dose and 50% reduced-dose abdominal CT: effect on image quality Kalra MK; Prasad S; Saini S; Blake MA; Varghese J; Halpern EF; Thrall JH; Rhea JTAJR Am J Roentgenol 2002[Nov]; 179 (5): 1101-6OBJECTIVE: We hypothesized that radiation doses for abdominal CT could be reduced by adjusting the dose for a patient's weight and cross-sectional abdominal dimensions, with the resultant scans still being of diagnostic quality. SUBJECTS AND METHODS: Using a multidetector CT scanner, we prospectively studied 39 patients who were 65 years and older who had a known history of cancer. After performing a diagnostic contrast-enhanced CT examination, we obtained four slices each (centered at the top of the right kidney) at a standard radiation dose (240-300 mA) and at a 50% reduced dose (120-150 mA) at a constant kilovoltage of 140. Scans were obtained during a single breath-hold, with a 2.5-mm detector configuration and a slice pitch of 6:1. Reconstructed slice thickness was 5 mm. In a blinded review, two radiologists rated the randomized CT scans for overall image quality and anatomic details of liver, spleen, adrenal glands, kidneys, pancreas, and abdominal wall, using a 5-point scale (1 = unacceptable, 2 = substandard, 3 = acceptable, 4 = above average, and 5 = superior). Patients' weight and abdominal circumference, area, and anteroposterior and transverse diameters were correlated with image quality of scans obtained at standard-dose and 50% reduced-dose CT. Statistical analysis of the data was performed using Wilcoxon's signed rank test. RESULTS: Overall, the image quality score was significantly higher (p < 0.005) on the scans obtained with standard-dose CT. No statistically significant difference in image quality was noted in the 50% reduced- and standard-dose CT scans in patients who weighed less than 180 lb, or 81 kg, (p > 0.05) and who had a transverse abdominal diameter of less than 34.5 cm (p > 0.05), an anteroposterior diameter of less than 28 cm (p > 0.05), a cross-sectional circumference of less than 105 cm (p > 0.05), and a cross-sectional area of less than 800 cm(2) (p > 0.05). Good interobserver agreement (p > 0.5) was found between the two reviewing radiologists. CONCLUSION: Abdominal CT scan quality appears to be acceptable even with a 50% reduction in radiation dose except in patients with large anthropometric measurements. A reduction in CT radiation dose is possible if the tube current is optimized for the patient's weight and abdominal dimensions.|*Radiography, Abdominal[MESH]|*Tomography, X-Ray Computed[MESH]|Abdomen/anatomy & histology[MESH]|Aged[MESH]|Aged, 80 and over[MESH]|Body Weight[MESH]|Female[MESH]|Humans[MESH]|Male[MESH]|Neoplasms/*diagnostic imaging[MESH]|Observer Variation[MESH]|Prospective Studies[MESH]|Radiation Dosage[MESH]|Radiographic Image Enhancement[MESH]|Statistics, Nonparametric[MESH] |